HomeLocationsTemaCarbon Capture & Storage (CCS)

Tema · Carbon Capture & Storage (CCS)

Valves for Carbon Capture & Storage (CCS) - Tema

Tema is Ghana's premier industrial and port city, anchored by the Tema Oil Refinery (TOR) and the new Sentuo Oil Refinery, the country's largest seaport, the VALCO aluminium smelter, the Tema thermal power enclave, and a dense food, beverage, and manufacturing belt across the Tema Industrial Area; valve demand spans refining and utilities - API 600 gate and globe valves, API 526 safety-relief valves, and fire-safe API 607 valves for the refineries and product terminals, API 6D ball valves for crude and refined-product transfer and tank-farm manifolds, ASME B16.34 gate and globe valves for power-plant steam and feedwater, and bronze and ductile-iron valves for the port, water, and food-processing utilities; refinery service requires NACE compliance for sour streams and EN 10204 3.1 MTCs; Vajra Industrial Solutions supplies Tema refining, power, port, and manufacturing buyers with API-certified, fire-safe, and utility valve packages with full export documentation and fast delivery to Ghana and West Africa.

SS316L gate and globe valves for amine absorber CO₂ capture, Class 900 Duplex ball valves for supercritical CO₂ compression and transport, and NACE-compliant valves for CO₂ geological storage.

NACE MR0175 / ISO 15156 (sour CO₂)ASME B16.34API 6DAPI 607 (Fire-Safe)ISO 15848-1 (Fugitive Emissions)
API 6D Certified
ASME B16.34
ISO 9001:2015
24h Quote

Carbon Capture & Storage (CCS) Valves - Available in Tema

Globe Valve (Amine Service)

Class 150 / 300

Lean/rich amine absorber and stripper - hot amine (MEA/MDEA) is corrosive; SS316L with Stellite trim for erosion control

Materials: A351 CF3M (SS316L cast) body; Stellite 6 seat and plug; PTFE packing  ·  Standards: API 623, BS 1873, ASME B16.34
View Globe Valve (Amine Service) options for Tema

Ball Valve (Supercritical CO₂)

Class 600 / 900

CO₂ compressor outlet and injection well isolation - supercritical CO₂ (> 73 bar) is an excellent solvent; seals must be CO₂-compatible

Materials: A890 Duplex 2205 or SS316L; PTFE seats; special CO₂-resistant elastomers (EPDM or HNBR rated for supercritical CO₂)  ·  Standards: API 6D, API 607, ISO 15848-1
View Ball Valve (Supercritical CO₂) options for Tema

Gate Valve (CO₂ Pipeline)

Class 300 / 600 / 900

CO₂ trunk pipeline isolation - API 6D full-bore gate valves; same specification as natural gas pipelines but with CO₂-compatible seals

Materials: A216 WCB with SS316 trim (dry CO₂); A182 F316L for wet CO₂ + H₂S service  ·  Standards: API 6D, API 600, ASME B16.34
View Gate Valve (CO₂ Pipeline) options for Tema

Check Valve (CO₂ Compressor)

Class 300 / 600

CO₂ compressor inter-stage and discharge back-flow prevention

Materials: A351 CF8M SS316; PTFE seat; SS316 spring  ·  Standards: API 594, API 6D, ASME B16.34
View Check Valve (CO₂ Compressor) options for Tema

Carbon Capture & Storage (CCS) Industry in Tema

Tema is Ghana's premier industrial and port city, anchored by the Tema Oil Refinery (TOR) and the new Sentuo Oil Refinery, the country's largest seaport, the VALCO aluminium smelter, the Tema thermal power enclave, and a dense food, beverage, and manufacturing belt across the Tema Industrial Area; valve demand spans refining and utilities - API 600 gate and globe valves, API 526 safety-relief valves, and fire-safe API 607 valves for the refineries and product terminals, API 6D ball valves for crude and refined-product transfer and tank-farm manifolds, ASME B16.34 gate and globe valves for power-plant steam and feedwater, and bronze and ductile-iron valves for the port, water, and food-processing utilities; refinery service requires NACE compliance for sour streams and EN 10204 3.1 MTCs; Vajra Industrial Solutions supplies Tema refining, power, port, and manufacturing buyers with API-certified, fire-safe, and utility valve packages with full export documentation and fast delivery to Ghana and West Africa.

Oil Refining (Tema Oil Refinery - TOR, Sentuo Oil Refinery)Ports & Logistics (Tema Port - Ghana's largest)Aluminium (VALCO smelter)Food & Beverage ProcessingPower Generation (Tema thermal plants)

Critical Valve Requirements

Wet CO₂ (CO₂ + H₂O) forms carbonic acid - attacks carbon steel at ppm level; SS316L mandatory for any wet CO₂ stream
Sour CO₂ (CO₂ + H₂S) - NACE MR0175 compliance required if H₂S partial pressure exceeds 0.0003 MPa threshold
Supercritical CO₂ seal compatibility - standard NBR/EPDM can swell and extrude in supercritical CO₂; only EPDM or HNBR grades specifically rated for CO₂ service
ISO 15848-1 fugitive emissions Class B or better - CCS projects have regulatory pressure to demonstrate zero leakage
Amine service valves - methyldiethanolamine (MDEA) and monoethanolamine (MEA) attack zinc and copper alloys; SS316L or WCB/SS316 trim only
Fire-safe API 607 for all CO₂ compressor and injection valve service - CO₂ does not burn, but co-firing with H₂S is a fire hazard in sour CCS

Why Tema's Oil Refining (Tema Oil Refinery - TOR, Sentuo Oil Refinery) Sector Needs Carbon Capture & Storage (CCS) Valves

Tema is Ghana's premier industrial and port city, anchored by the Tema Oil Refinery (TOR) and the new Sentuo Oil Refinery, the country's largest seaport, the VALCO aluminium smelter, the Tema thermal power enclave, and a dense food, beverage, and manufacturing belt across the Tema Industrial Area; valve demand spans refining and utilities - API 600 gate and globe valves, API 526 safety-relief valves, and fire-safe API 607 valves for the refineries and product terminals, API 6D ball valves for crude and refined-product transfer and tank-farm manifolds, ASME B16.34 gate and globe valves for power-plant steam and feedwater, and bronze and ductile-iron valves for the port, water, and food-processing utilities; refinery service requires NACE compliance for sour streams and EN 10204 3.1 MTCs; Vajra Industrial Solutions supplies Tema refining, power, port, and manufacturing buyers with API-certified, fire-safe, and utility valve packages with full export documentation and fast delivery to Ghana and West Africa. Key facilities in the Tema area - including Tema Oil Refinery (TOR), Tema Industrial Area Sectors, Tema Port and free zone - rely on Globe Valve (Amine Service) for their oil refining (tema oil refinery - tor, sentuo oil refinery) operations. Vajra Industrial Solutions supplies Globe Valve (Amine Service), Ball Valve (Supercritical CO₂), Gate Valve (CO₂ Pipeline), Check Valve (CO₂ Compressor) for carbon capture & storage (ccs) projects across Greater Accra, with full NACE MR0175 / ISO 15156 (sour CO₂) and ASME B16.34 compliance documentation - EN 10204 3.1 material test certificates, API 598 pressure test reports, and third-party inspection co-ordination available for every order.

Delivery to Tema

Vajra Industrial Solutions offers export documentation and delivery to Tema in 7–14 business days. Emergency dispatch available for plant shutdowns and critical site requirements.

Also serving: Tema Oil Refinery (TOR), Tema Industrial Area Sectors, Tema Port and free zone, Accra (25 km)

FAQ - Carbon Capture & Storage (CCS) Valves in Tema

Do you supply carbon capture & storage (ccs) valves in Tema?
Yes. Vajra Industrial Solutions supplies Globe Valve (Amine Service), Ball Valve (Supercritical CO₂), Gate Valve (CO₂ Pipeline), Check Valve (CO₂ Compressor) for carbon capture & storage (ccs) applications in Tema, Greater Accra. Tema is Ghana's premier industrial and port city, anchored by the Tema Oil Refinery (TOR) and the new Sentuo Oil Refinery, the country's largest seaport, the VALCO aluminium smelter, the Tema thermal power enclave, and a dense food, beverage, and manufacturing belt across the Tema Industrial Area; valve demand spans refining and utilities - API 600 gate and globe valves, API 526 safety-relief valves, and fire-safe API 607 valves for the refineries and product terminals, API 6D ball valves for crude and refined-product transfer and tank-farm manifolds, ASME B16.34 gate and globe valves for power-plant steam and feedwater, and bronze and ductile-iron valves for the port, water, and food-processing utilities; refinery service requires NACE compliance for sour streams and EN 10204 3.1 MTCs; Vajra Industrial Solutions supplies Tema refining, power, port, and manufacturing buyers with API-certified, fire-safe, and utility valve packages with full export documentation and fast delivery to Ghana and West Africa. We offer export documentation and delivery to Tema in 7–14 business days with full documentation and third-party inspection.
What certifications are required for carbon capture & storage (ccs) valves in Tema?
For carbon capture & storage (ccs) in Tema, the applicable standards are: NACE MR0175 / ISO 15156 (sour CO₂), ASME B16.34, API 6D, API 607 (Fire-Safe), ISO 15848-1 (Fugitive Emissions), API 598, ISO 21013 (CO₂ Safety). All valves are supplied with full documentation including material test reports (EN 10204 3.1/3.2), pressure test certificates, and dimensional inspection reports. Third-party inspection (TPI) by EIL, Bureau Veritas, Lloyd's Register, or the client's nominated inspector can be arranged.
What is the delivery time for carbon capture & storage (ccs) valves to Tema?
Standard stock sizes: export documentation and delivery to Tema in 7–14 business days. Custom sizes and special materials (Duplex, Hastelloy, P91): 4–8 weeks manufacturing lead time. Express dispatch available for urgent site requirements. Contact us at +91-9979774557 or sales@vajravyuh.com with your specification and required delivery date.
Can carbon steel valves be used in CO₂ service?
Dry CO₂ (water content below 50 ppm) does not corrode carbon steel - dried CO₂ from industrial sources is used in carbon steel pipelines. However, wet CO₂ (water-saturated gas or any liquid CO₂ + water) forms carbonic acid (pH ≈ 3.7 at 1 bar CO₂ partial pressure), which corrodes carbon steel rapidly (>10 mm/year in worst cases). Therefore: dry CO₂ pipeline and injection service - carbon steel A216 WCB acceptable with SS316 trim. Wet CO₂ anywhere in the process - SS316L mandatory. When in doubt, specify SS316L - the cost premium is small versus the corrosion risk.
What is the difference between CCS and carbon capture for enhanced oil recovery (CO₂-EOR)?
Carbon capture and storage (CCS) injects CO₂ into saline aquifers or depleted reservoirs for permanent geological storage. CO₂-EOR (Enhanced Oil Recovery) injects CO₂ into producing oil reservoirs to mobilise residual oil - the CO₂ is partially recycled from produced gas. Valve specifications are similar: both require Class 900–2500 forged SS316L or Duplex 2205 for injection service. CO₂-EOR streams have higher impurity (H₂S, hydrocarbons) requiring NACE MR0175. Pure CCS streams from power plant flue gas typically contain only CO₂ + traces of SO₂ and NOₓ - simpler chemistry, SS316L usually sufficient.

Other Application Guides for Tema

Get a Quote

Carbon Capture & Storage (CCS) Valves - Tema

Send your specification - quote within 24 hours with full documentation.

Standards

NACE MR0175 / ISO 15156 (sour CO₂)
ASME B16.34
API 6D
API 607 (Fire-Safe)
ISO 15848-1 (Fugitive Emissions)
API 598
ISO 21013 (CO₂ Safety)