HomeLocationsStockholmLNG & Cryogenic Service

Stockholm · LNG & Cryogenic Service

Valves for LNG & Cryogenic ServiceStockholm

Stockholm is Sweden's pharmaceutical and life sciences capital — AstraZeneca's Södertälje manufacturing campus (biologic and small-molecule APIs) requires sanitary SS 316L diaphragm valves, ASME BPE clean-steam ball valves, and USP Class VI compliant valves for GMP manufacturing; Stockholm's district heating network (Fortum Värme / Stockholm Exergi, ~12,000 MWh) uses ASME Class 150–300 gate valves and globe valves for heat exchange stations; Vajra Industrial Solutions supplies GMP-compliant sanitary valves for Stockholm pharma manufacturers, PED-certified steam gate and globe valves for district heating, and stainless steel butterfly valves for Stockholm Vatten water infrastructure.

Extended-bonnet ball, gate, and globe valves for LNG, liquid nitrogen, liquid oxygen, and other cryogenic service — low-temperature impact tested materials.

BS 6364 (Cryogenic valves)ASME B16.34 Annex FAPI 6DEN 13942ASTM A350 LF2 / LF3
API 6D Certified
ASME B16.34
ISO 9001:2015
24h Quote

LNG & Cryogenic Service Valves — Available in Stockholm

Cryogenic Ball Valve (Extended Bonnet)

Class 150 / 300 / 600 / 900

Quarter-turn operation with extended bonnet to keep packing above cryogenic temperature; fire-safe in LNG service

Materials: A351 CF8M, A182 F316L, A350 LF2 (forged) — SS 316 stem and trim  ·  Standards: BS 6364, API 6D, ASME B16.34, API 607
View Cryogenic Ball Valve (Extended Bonnet) options for Stockholm

Cryogenic Gate Valve (Extended Bonnet)

Class 150 / 300 / 600

Full-bore, straight-through isolation for LNG storage vessel and pipeline isolation

Materials: A350 LF2 (forged), A351 CF3M (cast SS316L low carbon), A182 F316L  ·  Standards: BS 6364, ASME B16.34, API 600
View Cryogenic Gate Valve (Extended Bonnet) options for Stockholm

Cryogenic Globe Valve (Extended Bonnet)

Class 150 / 300 / 600

Flow control and throttling in LNG process and vent/flare systems

Materials: A350 LF2, A182 F316L, A351 CF3M  ·  Standards: BS 6364, ASME B16.34
View Cryogenic Globe Valve (Extended Bonnet) options for Stockholm

Cryogenic Check Valve

Class 150 / 300

Non-return service on LNG pump discharge and send-out systems

Materials: A350 LF2, A351 CF8M, F316L  ·  Standards: BS 6364, API 594, ASME B16.34
View Cryogenic Check Valve options for Stockholm

LNG & Cryogenic Service Industry in Stockholm

Stockholm is Sweden's pharmaceutical and life sciences capital — AstraZeneca's Södertälje manufacturing campus (biologic and small-molecule APIs) requires sanitary SS 316L diaphragm valves, ASME BPE clean-steam ball valves, and USP Class VI compliant valves for GMP manufacturing; Stockholm's district heating network (Fortum Värme / Stockholm Exergi, ~12,000 MWh) uses ASME Class 150–300 gate valves and globe valves for heat exchange stations; Vajra Industrial Solutions supplies GMP-compliant sanitary valves for Stockholm pharma manufacturers, PED-certified steam gate and globe valves for district heating, and stainless steel butterfly valves for Stockholm Vatten water infrastructure.

Pharmaceuticals (AstraZeneca, Sobi)Chemical & Specialty ChemicalPower & District HeatingWater & WastewaterEngineering & Manufacturing

Critical Valve Requirements

Charpy V-notch impact testing at design temperature (−46°C to −196°C) per ASTM A370
Extended bonnet design to maintain stem packing above −20°C minimum
Cryogenic testing per BS 6364: gas bubble leak test at operating temperature
Materials: ASTM A350 LF2 (forged) or A351 CF8M/CF3M (cast) — not A216 WCB
Fire-safe design (API 607) for LNG and flammable cryogenic fluids
Full-bore design where pigging or slug control is required
Seat material rated for cryogenic temperature — PTFE (to −200°C) or PEEK

Why Stockholm's Pharmaceuticals (AstraZeneca, Sobi) Sector Needs LNG & Cryogenic Service Valves

Stockholm is Sweden's pharmaceutical and life sciences capital — AstraZeneca's Södertälje manufacturing campus (biologic and small-molecule APIs) requires sanitary SS 316L diaphragm valves, ASME BPE clean-steam ball valves, and USP Class VI compliant valves for GMP manufacturing; Stockholm's district heating network (Fortum Värme / Stockholm Exergi, ~12,000 MWh) uses ASME Class 150–300 gate valves and globe valves for heat exchange stations; Vajra Industrial Solutions supplies GMP-compliant sanitary valves for Stockholm pharma manufacturers, PED-certified steam gate and globe valves for district heating, and stainless steel butterfly valves for Stockholm Vatten water infrastructure. Key facilities in the Stockholm area — including AstraZeneca Södertälje manufacturing campus, Stockholm Vatten water utility infrastructure, Neste Nynäshamn renewable fuels terminal — rely on Cryogenic Ball Valve (Extended Bonnet) for their pharmaceuticals (astrazeneca, sobi) operations. Vajra Industrial Solutions supplies Cryogenic Ball Valve (Extended Bonnet), Cryogenic Gate Valve (Extended Bonnet), Cryogenic Globe Valve (Extended Bonnet), Cryogenic Check Valve for lng & cryogenic service projects across Stockholm County, with full BS 6364 (Cryogenic valves) and ASME B16.34 Annex F compliance documentation — EN 10204 3.1 material test certificates, API 598 pressure test reports, and third-party inspection co-ordination available for every order.

Delivery to Stockholm

Vajra Industrial Solutions offers export documentation and delivery to Stockholm in 7–14 business days. Emergency dispatch available for plant shutdowns and critical site requirements.

Also serving: AstraZeneca Södertälje manufacturing campus, Stockholm Vatten water utility infrastructure, Neste Nynäshamn renewable fuels terminal, Höganäs metal powder (north of Stockholm), LKAB logistics centre (iron ore supply chain)

FAQ — LNG & Cryogenic Service Valves in Stockholm

Do you supply lng & cryogenic service valves in Stockholm?
Yes. Vajra Industrial Solutions supplies Cryogenic Ball Valve (Extended Bonnet), Cryogenic Gate Valve (Extended Bonnet), Cryogenic Globe Valve (Extended Bonnet), Cryogenic Check Valve for lng & cryogenic service applications in Stockholm, Stockholm County. Stockholm is Sweden's pharmaceutical and life sciences capital — AstraZeneca's Södertälje manufacturing campus (biologic and small-molecule APIs) requires sanitary SS 316L diaphragm valves, ASME BPE clean-steam ball valves, and USP Class VI compliant valves for GMP manufacturing; Stockholm's district heating network (Fortum Värme / Stockholm Exergi, ~12,000 MWh) uses ASME Class 150–300 gate valves and globe valves for heat exchange stations; Vajra Industrial Solutions supplies GMP-compliant sanitary valves for Stockholm pharma manufacturers, PED-certified steam gate and globe valves for district heating, and stainless steel butterfly valves for Stockholm Vatten water infrastructure. We offer export documentation and delivery to Stockholm in 7–14 business days with full documentation and third-party inspection.
What certifications are required for lng & cryogenic service valves in Stockholm?
For lng & cryogenic service in Stockholm, the applicable standards are: BS 6364 (Cryogenic valves), ASME B16.34 Annex F, API 6D, EN 13942, ASTM A350 LF2 / LF3, ASTM A182 F316L, MSS SP-134. All valves are supplied with full documentation including material test reports (EN 10204 3.1/3.2), pressure test certificates, and dimensional inspection reports. Third-party inspection (TPI) by EIL, Bureau Veritas, Lloyd's Register, or the client's nominated inspector can be arranged.
What is the delivery time for lng & cryogenic service valves to Stockholm?
Standard stock sizes: export documentation and delivery to Stockholm in 7–14 business days. Custom sizes and special materials (Duplex, Hastelloy, P91): 4–8 weeks manufacturing lead time. Express dispatch available for urgent site requirements. Contact us at +91-9979774557 or sales@vajravyuh.com with your specification and required delivery date.
What is an extended bonnet on a cryogenic valve?
An extended bonnet (also called a top-entry or long-bonnet valve) has an elongated bonnet section that moves the stem packing away from the extremely cold process fluid. This prevents the packing material from being exposed to cryogenic temperature (where it would lose elasticity and leak), and prevents atmospheric moisture from freezing around the packing gland. The extension length is calculated based on the process temperature and the acceptable minimum packing temperature.
What ASTM material is used for cryogenic valves?
For LNG (−162°C) and liquid nitrogen (−196°C): ASTM A351 CF8M or CF3M (cast SS 316/316L) and ASTM A182 F316L (forged). For liquid CO₂ and −46°C service: ASTM A350 LF2 (forged low-temperature carbon steel), Charpy impact tested at −46°C. Standard A216 WCB carbon steel must never be used in cryogenic service below −29°C.

Other Application Guides for Stockholm

Get a Quote

LNG & Cryogenic Service Valves — Stockholm

Send your specification — quote within 24 hours with full documentation.

Standards

BS 6364 (Cryogenic valves)
ASME B16.34 Annex F
API 6D
EN 13942
ASTM A350 LF2 / LF3
ASTM A182 F316L
MSS SP-134