HomeLocationsCilacapGeothermal Power Plants

Cilacap · Geothermal Power Plants

Valves for Geothermal Power Plants - Cilacap

Cilacap on the south coast of Central Java is the site of Pertamina's Refinery Unit IV - Indonesia's largest refinery at around 348,000 bpd - integrated with paraxylene, aromatics, and lube base-oil units, alongside a major coal-fired power complex, a large cement plant, and the Tanjung Intan port; refinery, petrochemical, and power service demands a broad valve portfolio to Pertamina and licensor standards - API 6D ball, gate, and check valves in A216 WCB and A351 CF8M for crude, product, and gas lines, NACE MR0175 valves for hydrotreating and sour service, high-temperature WC9 and F22 valves for hydrocracker, platformer, and CDU/VDU duty, fire-safe API 607 valves throughout, IBR-equivalent and ASME B16.34 steam valves for the power plant, knife gate and pinch valves for coal and ash handling, and API 526 safety-relief valves for reactor and boiler protection; SNI conformity, PIB customs documentation, and full MTCs are required; Vajra Industrial Solutions supplies Cilacap refinery, petrochemical, and power buyers and their turnaround and EPC contractors with API 6D, NACE, high-temperature, fire-safe, and abrasion-resistant valve packages with full traceability and export documentation to Indonesia.

Duplex 2205 wellhead isolation ball valves, NACE MR0175 gate valves for H₂S-containing geothermal brine, and IBR-certified steam valves for geothermal power generation.

NACE MR0175 / ISO 15156ASME B16.34IBR 1950 (Steam India)API 600API 6D
API 6D Certified
ASME B16.34
ISO 9001:2015
24h Quote

Geothermal Power Plants Valves - Available in Cilacap

Ball Valve (Duplex 2205)

Class 600 / 900

Wellhead isolation and Christmas tree - sour brine (H₂S + CO₂ + Cl⁻) at 200–300°C; fire-safe, anti-static

Materials: A890 Grade 1B Duplex 2205 body and ball; Duplex stem; PTFE seats with metal seat backup  ·  Standards: API 6D, NACE MR0175, API 607 (fire-safe), ISO 14313
View Ball Valve (Duplex 2205) options for Cilacap

Gate Valve (NACE MR0175)

Class 300 / 600

Brine pipeline isolation and separator inlet - sour H₂S service; Class 300–600

Materials: A216 WCB with SS316 trim (NACE HRC ≤ 22); A890 Duplex for higher chloride fields  ·  Standards: API 600, NACE MR0175, ASME B16.34
View Gate Valve (NACE MR0175) options for Cilacap

Butterfly Valve (SS316L)

Class 150 / 300

Geothermal brine reinjection headers (large bore, moderate pressure), cooling water, and condensate service

Materials: SS316L disc and shaft; EPDM seat; WCB body with SS316L overlay in contact areas  ·  Standards: API 609, ASME B16.34
View Butterfly Valve (SS316L) options for Cilacap

Gate Valve (IBR Steam)

Class 150 / 300

Geothermal steam turbine inlet isolation and extraction steam - IBR mandatory in Indian geothermal projects

Materials: A216 WCB (saturated steam to 180°C); SS316 trim for H₂S-containing steam  ·  Standards: IBR 1950, ASME B16.34, API 600
View Gate Valve (IBR Steam) options for Cilacap

Geothermal Power Plants Industry in Cilacap

Cilacap on the south coast of Central Java is the site of Pertamina's Refinery Unit IV - Indonesia's largest refinery at around 348,000 bpd - integrated with paraxylene, aromatics, and lube base-oil units, alongside a major coal-fired power complex, a large cement plant, and the Tanjung Intan port; refinery, petrochemical, and power service demands a broad valve portfolio to Pertamina and licensor standards - API 6D ball, gate, and check valves in A216 WCB and A351 CF8M for crude, product, and gas lines, NACE MR0175 valves for hydrotreating and sour service, high-temperature WC9 and F22 valves for hydrocracker, platformer, and CDU/VDU duty, fire-safe API 607 valves throughout, IBR-equivalent and ASME B16.34 steam valves for the power plant, knife gate and pinch valves for coal and ash handling, and API 526 safety-relief valves for reactor and boiler protection; SNI conformity, PIB customs documentation, and full MTCs are required; Vajra Industrial Solutions supplies Cilacap refinery, petrochemical, and power buyers and their turnaround and EPC contractors with API 6D, NACE, high-temperature, fire-safe, and abrasion-resistant valve packages with full traceability and export documentation to Indonesia.

Refining (Pertamina Cilacap Refinery - ~348,000 bpd, Indonesia's largest)Petrochemicals (paraxylene, aromatics, lube base oils)Power Generation (Cilacap coal-fired power complex)Cement (Holcim/Solusi Bangun Indonesia)Ports & EPC

Critical Valve Requirements

H₂S service - NACE MR0175 / ISO 15156 mandatory for all wetted metallic components; HRC ≤ 22 Rockwell hardness limit on body, trim, and fasteners
Silica scaling - full-bore valves only; no throttle positions; pipeline injection of scale inhibitor upstream of brine valves
Two-phase flow (steam + liquid brine) - metal-to-metal seat or reinforced PTFE; no soft-seat-only designs in wellhead service
IBR certification for steam turbine supply headers in India - Form III-C material and Form III-E hydraulic test certificates mandatory
Chloride stress corrosion - Duplex 2205 or SS316L (not SS304); super duplex 2507 for high-chloride (>5,000 ppm Cl⁻) fields
Geothermal flash steam often contains non-condensable gases (NCG: H₂S, CO₂, NH₃) - valve materials must resist corrosion in this mixture

Why Cilacap's Refining (Pertamina Cilacap Refinery - ~348,000 bpd, Indonesia's largest) Sector Needs Geothermal Power Plants Valves

Cilacap on the south coast of Central Java is the site of Pertamina's Refinery Unit IV - Indonesia's largest refinery at around 348,000 bpd - integrated with paraxylene, aromatics, and lube base-oil units, alongside a major coal-fired power complex, a large cement plant, and the Tanjung Intan port; refinery, petrochemical, and power service demands a broad valve portfolio to Pertamina and licensor standards - API 6D ball, gate, and check valves in A216 WCB and A351 CF8M for crude, product, and gas lines, NACE MR0175 valves for hydrotreating and sour service, high-temperature WC9 and F22 valves for hydrocracker, platformer, and CDU/VDU duty, fire-safe API 607 valves throughout, IBR-equivalent and ASME B16.34 steam valves for the power plant, knife gate and pinch valves for coal and ash handling, and API 526 safety-relief valves for reactor and boiler protection; SNI conformity, PIB customs documentation, and full MTCs are required; Vajra Industrial Solutions supplies Cilacap refinery, petrochemical, and power buyers and their turnaround and EPC contractors with API 6D, NACE, high-temperature, fire-safe, and abrasion-resistant valve packages with full traceability and export documentation to Indonesia. Key facilities in the Cilacap area - including Pertamina Refinery Unit IV (RU IV) Cilacap, Cilacap aromatics and lube base-oil plants, Cilacap coal-fired power station (S2P / Sumber Segara Primadaya) - rely on Ball Valve (Duplex 2205) for their refining (pertamina cilacap refinery - ~348,000 bpd, indonesia's largest) operations. Vajra Industrial Solutions supplies Ball Valve (Duplex 2205), Gate Valve (NACE MR0175), Butterfly Valve (SS316L), Gate Valve (IBR Steam) for geothermal power plants projects across Central Java, with full NACE MR0175 / ISO 15156 and ASME B16.34 compliance documentation - EN 10204 3.1 material test certificates, API 598 pressure test reports, and third-party inspection co-ordination available for every order.

Delivery to Cilacap

Vajra Industrial Solutions offers export documentation and delivery to Cilacap in 7–14 business days. Emergency dispatch available for plant shutdowns and critical site requirements.

Also serving: Pertamina Refinery Unit IV (RU IV) Cilacap, Cilacap aromatics and lube base-oil plants, Cilacap coal-fired power station (S2P / Sumber Segara Primadaya), Solusi Bangun Indonesia (Holcim) cement plant and Tanjung Intan port

FAQ - Geothermal Power Plants Valves in Cilacap

Do you supply geothermal power plants valves in Cilacap?
Yes. Vajra Industrial Solutions supplies Ball Valve (Duplex 2205), Gate Valve (NACE MR0175), Butterfly Valve (SS316L), Gate Valve (IBR Steam) for geothermal power plants applications in Cilacap, Central Java. Cilacap on the south coast of Central Java is the site of Pertamina's Refinery Unit IV - Indonesia's largest refinery at around 348,000 bpd - integrated with paraxylene, aromatics, and lube base-oil units, alongside a major coal-fired power complex, a large cement plant, and the Tanjung Intan port; refinery, petrochemical, and power service demands a broad valve portfolio to Pertamina and licensor standards - API 6D ball, gate, and check valves in A216 WCB and A351 CF8M for crude, product, and gas lines, NACE MR0175 valves for hydrotreating and sour service, high-temperature WC9 and F22 valves for hydrocracker, platformer, and CDU/VDU duty, fire-safe API 607 valves throughout, IBR-equivalent and ASME B16.34 steam valves for the power plant, knife gate and pinch valves for coal and ash handling, and API 526 safety-relief valves for reactor and boiler protection; SNI conformity, PIB customs documentation, and full MTCs are required; Vajra Industrial Solutions supplies Cilacap refinery, petrochemical, and power buyers and their turnaround and EPC contractors with API 6D, NACE, high-temperature, fire-safe, and abrasion-resistant valve packages with full traceability and export documentation to Indonesia. We offer export documentation and delivery to Cilacap in 7–14 business days with full documentation and third-party inspection.
What certifications are required for geothermal power plants valves in Cilacap?
For geothermal power plants in Cilacap, the applicable standards are: NACE MR0175 / ISO 15156, ASME B16.34, IBR 1950 (Steam India), API 600, API 6D, API 598, ISO 9001:2015. All valves are supplied with full documentation including material test reports (EN 10204 3.1/3.2), pressure test certificates, and dimensional inspection reports. Third-party inspection (TPI) by EIL, Bureau Veritas, Lloyd's Register, or the client's nominated inspector can be arranged.
What is the delivery time for geothermal power plants valves to Cilacap?
Standard stock sizes: export documentation and delivery to Cilacap in 7–14 business days. Custom sizes and special materials (Duplex, Hastelloy, P91): 4–8 weeks manufacturing lead time. Express dispatch available for urgent site requirements. Contact us at +91-9979774557 or sales@vajravyuh.com with your specification and required delivery date.
What material is recommended for geothermal brine with high H₂S?
For geothermal brine containing H₂S above 0.0003 MPa partial pressure (the NACE MR0175 threshold), specify Duplex 2205 (ASTM A890 Grade 1B) with hardness confirmed ≤ HRC 22 as per NACE MR0175 / ISO 15156. Duplex 2205 provides both corrosion resistance (PREN ≥ 35) and the required hardness limit. For very high H₂S fields (> 1,000 ppm) or combined high chloride + H₂S, upgrade to Super Duplex 2507 (PREN ≥ 40). Carbon steel with SS316 trim is acceptable only for H₂S below the NACE threshold.
How does silica scaling affect valve selection for geothermal brine?
Silica (SiO₂) dissolved in geothermal brine precipitates when the brine cools below the silica saturation temperature (typically 80–120°C for high-silica fields). This scale deposits on valve seats, stems, and body ports, causing seizure and leakage. Mitigation: (1) use full-bore valves - no narrow ports where scale can bridge; (2) use ball valves in the full-open position only - do not use ball valves for throttling in scaling brine (scale deposits in the partially open cavity); (3) inject scale inhibitor upstream. Knife gate valves for slurry-heavy brine cut through scale deposits better than wedge gate.

Other Application Guides for Cilacap

Get a Quote

Geothermal Power Plants Valves - Cilacap

Send your specification - quote within 24 hours with full documentation.

Standards

NACE MR0175 / ISO 15156
ASME B16.34
IBR 1950 (Steam India)
API 600
API 6D
API 598
ISO 9001:2015