HomeLocationsCilacapLNG & Cryogenic Service

Cilacap · LNG & Cryogenic Service

Valves for LNG & Cryogenic Service - Cilacap

Cilacap on the south coast of Central Java is the site of Pertamina's Refinery Unit IV - Indonesia's largest refinery at around 348,000 bpd - integrated with paraxylene, aromatics, and lube base-oil units, alongside a major coal-fired power complex, a large cement plant, and the Tanjung Intan port; refinery, petrochemical, and power service demands a broad valve portfolio to Pertamina and licensor standards - API 6D ball, gate, and check valves in A216 WCB and A351 CF8M for crude, product, and gas lines, NACE MR0175 valves for hydrotreating and sour service, high-temperature WC9 and F22 valves for hydrocracker, platformer, and CDU/VDU duty, fire-safe API 607 valves throughout, IBR-equivalent and ASME B16.34 steam valves for the power plant, knife gate and pinch valves for coal and ash handling, and API 526 safety-relief valves for reactor and boiler protection; SNI conformity, PIB customs documentation, and full MTCs are required; Vajra Industrial Solutions supplies Cilacap refinery, petrochemical, and power buyers and their turnaround and EPC contractors with API 6D, NACE, high-temperature, fire-safe, and abrasion-resistant valve packages with full traceability and export documentation to Indonesia.

Extended-bonnet ball, gate, and globe valves for LNG, liquid nitrogen, liquid oxygen, and other cryogenic service - low-temperature impact tested materials.

BS 6364 (Cryogenic valves)ASME B16.34 Annex FAPI 6DEN 13942ASTM A350 LF2 / LF3
API 6D Certified
ASME B16.34
ISO 9001:2015
24h Quote

LNG & Cryogenic Service Valves - Available in Cilacap

Cryogenic Ball Valve (Extended Bonnet)

Class 150 / 300 / 600 / 900

Quarter-turn operation with extended bonnet to keep packing above cryogenic temperature; fire-safe in LNG service

Materials: A351 CF8M, A182 F316L, A350 LF2 (forged) - SS 316 stem and trim  ·  Standards: BS 6364, API 6D, ASME B16.34, API 607
View Cryogenic Ball Valve (Extended Bonnet) options for Cilacap

Cryogenic Gate Valve (Extended Bonnet)

Class 150 / 300 / 600

Full-bore, straight-through isolation for LNG storage vessel and pipeline isolation

Materials: A350 LF2 (forged), A351 CF3M (cast SS316L low carbon), A182 F316L  ·  Standards: BS 6364, ASME B16.34, API 600
View Cryogenic Gate Valve (Extended Bonnet) options for Cilacap

Cryogenic Globe Valve (Extended Bonnet)

Class 150 / 300 / 600

Flow control and throttling in LNG process and vent/flare systems

Materials: A350 LF2, A182 F316L, A351 CF3M  ·  Standards: BS 6364, ASME B16.34
View Cryogenic Globe Valve (Extended Bonnet) options for Cilacap

Cryogenic Check Valve

Class 150 / 300

Non-return service on LNG pump discharge and send-out systems

Materials: A350 LF2, A351 CF8M, F316L  ·  Standards: BS 6364, API 594, ASME B16.34
View Cryogenic Check Valve options for Cilacap

LNG & Cryogenic Service Industry in Cilacap

Cilacap on the south coast of Central Java is the site of Pertamina's Refinery Unit IV - Indonesia's largest refinery at around 348,000 bpd - integrated with paraxylene, aromatics, and lube base-oil units, alongside a major coal-fired power complex, a large cement plant, and the Tanjung Intan port; refinery, petrochemical, and power service demands a broad valve portfolio to Pertamina and licensor standards - API 6D ball, gate, and check valves in A216 WCB and A351 CF8M for crude, product, and gas lines, NACE MR0175 valves for hydrotreating and sour service, high-temperature WC9 and F22 valves for hydrocracker, platformer, and CDU/VDU duty, fire-safe API 607 valves throughout, IBR-equivalent and ASME B16.34 steam valves for the power plant, knife gate and pinch valves for coal and ash handling, and API 526 safety-relief valves for reactor and boiler protection; SNI conformity, PIB customs documentation, and full MTCs are required; Vajra Industrial Solutions supplies Cilacap refinery, petrochemical, and power buyers and their turnaround and EPC contractors with API 6D, NACE, high-temperature, fire-safe, and abrasion-resistant valve packages with full traceability and export documentation to Indonesia.

Refining (Pertamina Cilacap Refinery - ~348,000 bpd, Indonesia's largest)Petrochemicals (paraxylene, aromatics, lube base oils)Power Generation (Cilacap coal-fired power complex)Cement (Holcim/Solusi Bangun Indonesia)Ports & EPC

Critical Valve Requirements

Charpy V-notch impact testing at design temperature (−46°C to −196°C) per ASTM A370
Extended bonnet design to maintain stem packing above −20°C minimum
Cryogenic testing per BS 6364: gas bubble leak test at operating temperature
Materials: ASTM A350 LF2 (forged) or A351 CF8M/CF3M (cast) - not A216 WCB
Fire-safe design (API 607) for LNG and flammable cryogenic fluids
Full-bore design where pigging or slug control is required
Seat material rated for cryogenic temperature - PTFE (to −200°C) or PEEK

Why Cilacap's Refining (Pertamina Cilacap Refinery - ~348,000 bpd, Indonesia's largest) Sector Needs LNG & Cryogenic Service Valves

Cilacap on the south coast of Central Java is the site of Pertamina's Refinery Unit IV - Indonesia's largest refinery at around 348,000 bpd - integrated with paraxylene, aromatics, and lube base-oil units, alongside a major coal-fired power complex, a large cement plant, and the Tanjung Intan port; refinery, petrochemical, and power service demands a broad valve portfolio to Pertamina and licensor standards - API 6D ball, gate, and check valves in A216 WCB and A351 CF8M for crude, product, and gas lines, NACE MR0175 valves for hydrotreating and sour service, high-temperature WC9 and F22 valves for hydrocracker, platformer, and CDU/VDU duty, fire-safe API 607 valves throughout, IBR-equivalent and ASME B16.34 steam valves for the power plant, knife gate and pinch valves for coal and ash handling, and API 526 safety-relief valves for reactor and boiler protection; SNI conformity, PIB customs documentation, and full MTCs are required; Vajra Industrial Solutions supplies Cilacap refinery, petrochemical, and power buyers and their turnaround and EPC contractors with API 6D, NACE, high-temperature, fire-safe, and abrasion-resistant valve packages with full traceability and export documentation to Indonesia. Key facilities in the Cilacap area - including Pertamina Refinery Unit IV (RU IV) Cilacap, Cilacap aromatics and lube base-oil plants, Cilacap coal-fired power station (S2P / Sumber Segara Primadaya) - rely on Cryogenic Ball Valve (Extended Bonnet) for their refining (pertamina cilacap refinery - ~348,000 bpd, indonesia's largest) operations. Vajra Industrial Solutions supplies Cryogenic Ball Valve (Extended Bonnet), Cryogenic Gate Valve (Extended Bonnet), Cryogenic Globe Valve (Extended Bonnet), Cryogenic Check Valve for lng & cryogenic service projects across Central Java, with full BS 6364 (Cryogenic valves) and ASME B16.34 Annex F compliance documentation - EN 10204 3.1 material test certificates, API 598 pressure test reports, and third-party inspection co-ordination available for every order.

Delivery to Cilacap

Vajra Industrial Solutions offers export documentation and delivery to Cilacap in 7–14 business days. Emergency dispatch available for plant shutdowns and critical site requirements.

Also serving: Pertamina Refinery Unit IV (RU IV) Cilacap, Cilacap aromatics and lube base-oil plants, Cilacap coal-fired power station (S2P / Sumber Segara Primadaya), Solusi Bangun Indonesia (Holcim) cement plant and Tanjung Intan port

FAQ - LNG & Cryogenic Service Valves in Cilacap

Do you supply lng & cryogenic service valves in Cilacap?
Yes. Vajra Industrial Solutions supplies Cryogenic Ball Valve (Extended Bonnet), Cryogenic Gate Valve (Extended Bonnet), Cryogenic Globe Valve (Extended Bonnet), Cryogenic Check Valve for lng & cryogenic service applications in Cilacap, Central Java. Cilacap on the south coast of Central Java is the site of Pertamina's Refinery Unit IV - Indonesia's largest refinery at around 348,000 bpd - integrated with paraxylene, aromatics, and lube base-oil units, alongside a major coal-fired power complex, a large cement plant, and the Tanjung Intan port; refinery, petrochemical, and power service demands a broad valve portfolio to Pertamina and licensor standards - API 6D ball, gate, and check valves in A216 WCB and A351 CF8M for crude, product, and gas lines, NACE MR0175 valves for hydrotreating and sour service, high-temperature WC9 and F22 valves for hydrocracker, platformer, and CDU/VDU duty, fire-safe API 607 valves throughout, IBR-equivalent and ASME B16.34 steam valves for the power plant, knife gate and pinch valves for coal and ash handling, and API 526 safety-relief valves for reactor and boiler protection; SNI conformity, PIB customs documentation, and full MTCs are required; Vajra Industrial Solutions supplies Cilacap refinery, petrochemical, and power buyers and their turnaround and EPC contractors with API 6D, NACE, high-temperature, fire-safe, and abrasion-resistant valve packages with full traceability and export documentation to Indonesia. We offer export documentation and delivery to Cilacap in 7–14 business days with full documentation and third-party inspection.
What certifications are required for lng & cryogenic service valves in Cilacap?
For lng & cryogenic service in Cilacap, the applicable standards are: BS 6364 (Cryogenic valves), ASME B16.34 Annex F, API 6D, EN 13942, ASTM A350 LF2 / LF3, ASTM A182 F316L, MSS SP-134. All valves are supplied with full documentation including material test reports (EN 10204 3.1/3.2), pressure test certificates, and dimensional inspection reports. Third-party inspection (TPI) by EIL, Bureau Veritas, Lloyd's Register, or the client's nominated inspector can be arranged.
What is the delivery time for lng & cryogenic service valves to Cilacap?
Standard stock sizes: export documentation and delivery to Cilacap in 7–14 business days. Custom sizes and special materials (Duplex, Hastelloy, P91): 4–8 weeks manufacturing lead time. Express dispatch available for urgent site requirements. Contact us at +91-9979774557 or sales@vajravyuh.com with your specification and required delivery date.
What is an extended bonnet on a cryogenic valve?
An extended bonnet (also called a top-entry or long-bonnet valve) has an elongated bonnet section that moves the stem packing away from the extremely cold process fluid. This prevents the packing material from being exposed to cryogenic temperature (where it would lose elasticity and leak), and prevents atmospheric moisture from freezing around the packing gland. The extension length is calculated based on the process temperature and the acceptable minimum packing temperature.
What ASTM material is used for cryogenic valves?
For LNG (−162°C) and liquid nitrogen (−196°C): ASTM A351 CF8M or CF3M (cast SS 316/316L) and ASTM A182 F316L (forged). For liquid CO₂ and −46°C service: ASTM A350 LF2 (forged low-temperature carbon steel), Charpy impact tested at −46°C. Standard A216 WCB carbon steel must never be used in cryogenic service below −29°C.

Other Application Guides for Cilacap

Get a Quote

LNG & Cryogenic Service Valves - Cilacap

Send your specification - quote within 24 hours with full documentation.

Standards

BS 6364 (Cryogenic valves)
ASME B16.34 Annex F
API 6D
EN 13942
ASTM A350 LF2 / LF3
ASTM A182 F316L
MSS SP-134