Dhamra · Offshore & Subsea Applications
Valves for Offshore & Subsea Applications - Dhamra
Dhamra on the Odisha coast hosts the Dhamra LNG Terminal (a 5 MTPA Adani-TotalEnergies regasification facility feeding the eastern India gas grid) alongside the deep-water Dhamra Port and its bulk-cargo and fertiliser-feedstock traffic; cryogenic LNG regas, jetty, and gas-grid service drives demand for extended-bonnet cryogenic ball and gate valves in A352 LCC for -162 degrees C LNG lines (per BS 6364), API 6D pipeline valves for send-out gas headers, ESD and double-block-and-bleed valves for custody-transfer and safety isolation, and seawater-service duplex stainless butterfly and check valves for seawater vaporiser and cooling loops; ASME B16.34, API 6D, and NFPA 59A LNG standards apply with fugitive-emission and cryogenic type testing; Vajra Industrial Solutions supplies Dhamra LNG, port, and pipeline operators with cryogenic and pipeline valve packages and eastern-India logistics.
NORSOK M-630, API 17D, and DNV-certified Duplex/Super Duplex and Inconel valves for topside process, subsea wellhead, FPSO, and offshore platform applications.
Offshore & Subsea Applications Valves - Available in Dhamra
Trunnion Ball Valve (Duplex/Super Duplex)
Class 600 / 900 / 1500Topside process isolation; pig launcher/receiver; manifold isolation; ESD on production headers
Gate Valve (Inconel Overlay)
Class 2500 / API 10,000 psi / 15,000 psiSubsea wellhead isolation, Xmas tree production master and swab valves
Butterfly Valve (NORSOK-compliant)
Class 150 / 300Large-bore seawater cooling, firewater, and ballast water treatment isolation
Check Valve (Duplex)
Class 600 / 900Production header, gas lift, and chemical injection back-flow prevention
Offshore & Subsea Applications Industry in Dhamra
Dhamra on the Odisha coast hosts the Dhamra LNG Terminal (a 5 MTPA Adani-TotalEnergies regasification facility feeding the eastern India gas grid) alongside the deep-water Dhamra Port and its bulk-cargo and fertiliser-feedstock traffic; cryogenic LNG regas, jetty, and gas-grid service drives demand for extended-bonnet cryogenic ball and gate valves in A352 LCC for -162 degrees C LNG lines (per BS 6364), API 6D pipeline valves for send-out gas headers, ESD and double-block-and-bleed valves for custody-transfer and safety isolation, and seawater-service duplex stainless butterfly and check valves for seawater vaporiser and cooling loops; ASME B16.34, API 6D, and NFPA 59A LNG standards apply with fugitive-emission and cryogenic type testing; Vajra Industrial Solutions supplies Dhamra LNG, port, and pipeline operators with cryogenic and pipeline valve packages and eastern-India logistics.
Critical Valve Requirements
Why Dhamra's LNG Regasification Sector Needs Offshore & Subsea Applications Valves
Dhamra on the Odisha coast hosts the Dhamra LNG Terminal (a 5 MTPA Adani-TotalEnergies regasification facility feeding the eastern India gas grid) alongside the deep-water Dhamra Port and its bulk-cargo and fertiliser-feedstock traffic; cryogenic LNG regas, jetty, and gas-grid service drives demand for extended-bonnet cryogenic ball and gate valves in A352 LCC for -162 degrees C LNG lines (per BS 6364), API 6D pipeline valves for send-out gas headers, ESD and double-block-and-bleed valves for custody-transfer and safety isolation, and seawater-service duplex stainless butterfly and check valves for seawater vaporiser and cooling loops; ASME B16.34, API 6D, and NFPA 59A LNG standards apply with fugitive-emission and cryogenic type testing; Vajra Industrial Solutions supplies Dhamra LNG, port, and pipeline operators with cryogenic and pipeline valve packages and eastern-India logistics. Key facilities in the Dhamra area - including Dhamra LNG Terminal, Dhamra Port, Bhadrak industrial corridor - rely on Trunnion Ball Valve (Duplex/Super Duplex) for their port & bulk handling operations. Vajra Industrial Solutions supplies Trunnion Ball Valve (Duplex/Super Duplex), Gate Valve (Inconel Overlay), Butterfly Valve (NORSOK-compliant), Check Valve (Duplex) for offshore & subsea applications projects across Odisha, with full NORSOK M-630 and API 6D compliance documentation - EN 10204 3.1 material test certificates, API 598 pressure test reports, and third-party inspection co-ordination available for every order.
Delivery to Dhamra
Vajra Industrial Solutions offers delivery to Dhamra in 3–7 business days. Emergency dispatch available for plant shutdowns and critical site requirements.
Also serving: Dhamra LNG Terminal, Dhamra Port, Bhadrak industrial corridor, Paradip-Dhamra pipeline zone
FAQ - Offshore & Subsea Applications Valves in Dhamra
Do you supply offshore & subsea applications valves in Dhamra?
What certifications are required for offshore & subsea applications valves in Dhamra?
What is the delivery time for offshore & subsea applications valves to Dhamra?
What is NORSOK M-630 and when does it apply?
What duplex grade should I specify for offshore seawater service?
Other Application Guides for Dhamra
Get a Quote
Offshore & Subsea Applications Valves - Dhamra
Send your specification - quote within 24 hours with full documentation.
Standards
Product Categories