HomeLocationsTakoradiAir Separation Units (ASU)

Takoradi · Air Separation Units (ASU)

Valves for Air Separation Units (ASU) - Takoradi

Takoradi (Sekondi-Takoradi) in Ghana's Western Region is the onshore hub for the country's offshore oil-and-gas industry, serving the Jubilee and TEN FPSO fields, hosting the Ghana Gas Atuabo processing plant, the Takoradi thermal power enclave at Aboadze, and a busy port that handles oil-and-gas logistics and manganese and bauxite exports; upstream support, gas processing, and power generation drive demand for API 6D ball, gate, and check valves in A216 WCB and duplex for oil, gas, and export lines, NACE MR0175 sour-service valves for gas streams, API 609 butterfly valves for cooling and firewater, severe-service control valves and API 526 safety-relief valves for the power plants, and ESD valves for the terminals; ASME B16.34, B16.5, and international offshore/EPC standards apply with full material traceability and PMI; Vajra Industrial Solutions supplies Takoradi oil-and-gas support bases, gas-plant and power operators, and EPC contractors with API 6D, NACE, duplex, and severe-service valve packages with documentation and West Africa delivery.

ASTM G93 oxygen-cleaned cryogenic extended-bonnet SS316L ball and gate valves for ASU liquid oxygen (LOX), liquid nitrogen (LIN), and liquid argon (LAR) production columns.

ASTM G93 (Oxygen Cleaning)EIGA Doc 13 (Oxygen Safety)BS 6364 (Cryogenic Valves)ASME B16.34ISO 21011 (Cryogenic Valves)
API 6D Certified
ASME B16.34
ISO 9001:2015
24h Quote

Air Separation Units (ASU) Valves - Available in Takoradi

Cryogenic Ball Valve (LOX Service)

Class 150 / 300

LOX pump suction, LOX column draw, LOX product loading - extended bonnet for −183°C; ASTM G93 oxygen-cleaned

Materials: A182 F316L forged body; SS316L ball; PCTFE seats (oxygen-compatible); SS316L extended bonnet (350+ mm)  ·  Standards: BS 6364, ASTM G93, EIGA Doc 13, API 607 (fire-safe, oxygen-critical)
View Cryogenic Ball Valve (LOX Service) options for Takoradi

Cryogenic Gate Valve (LIN/LAR)

Class 150 / 300

Liquid nitrogen and argon column isolation, product draw, and storage tank isolation; extended bonnet required

Materials: A182 F316L body and stem; SS316L gate and seats; extended bonnet per BS 6364  ·  Standards: BS 6364, ASME B16.34, ISO 21011
View Cryogenic Gate Valve (LIN/LAR) options for Takoradi

Globe Valve (Control, Cryogenic)

Class 150 / 300

Oxygen pressure letdown and LIN flow control - precision control; SS316L body; no elastomer seats in oxygen service

Materials: A182 F316L body; SS316L trim; PCTFE or SS316 seat; oxygen-cleaned  ·  Standards: BS 6364, ASTM G93, ASME B16.34
View Globe Valve (Control, Cryogenic) options for Takoradi

Check Valve (Cryogenic)

Class 150 / 300

LOX pump discharge check, back-flow prevention on product filling headers

Materials: A182 F316L body; SS316L disc and hinge pin; PCTFE seat ring; oxygen-cleaned  ·  Standards: BS 6364, API 594, ASTM G93
View Check Valve (Cryogenic) options for Takoradi

Air Separation Units (ASU) Industry in Takoradi

Takoradi (Sekondi-Takoradi) in Ghana's Western Region is the onshore hub for the country's offshore oil-and-gas industry, serving the Jubilee and TEN FPSO fields, hosting the Ghana Gas Atuabo processing plant, the Takoradi thermal power enclave at Aboadze, and a busy port that handles oil-and-gas logistics and manganese and bauxite exports; upstream support, gas processing, and power generation drive demand for API 6D ball, gate, and check valves in A216 WCB and duplex for oil, gas, and export lines, NACE MR0175 sour-service valves for gas streams, API 609 butterfly valves for cooling and firewater, severe-service control valves and API 526 safety-relief valves for the power plants, and ESD valves for the terminals; ASME B16.34, B16.5, and international offshore/EPC standards apply with full material traceability and PMI; Vajra Industrial Solutions supplies Takoradi oil-and-gas support bases, gas-plant and power operators, and EPC contractors with API 6D, NACE, duplex, and severe-service valve packages with documentation and West Africa delivery.

Offshore Oil & Gas Support (Jubilee & TEN fields)Gas Processing (Ghana Gas Atuabo plant)Thermal Power Generation (Takoradi T1/T2/T3)Port & Marine LogisticsMining Export & Manganese

Critical Valve Requirements

ASTM G93 / CGA G-4.1 oxygen cleaning - all valves for LOX/GOX service must be degreased with approved solvents, then passivated; verified by UV light and/or white glove test; sealed in nitrogen-purged bags until installation
EIGA Doc 13 (European Industrial Gases Association) - comprehensive oxygen safety standard; defines material compatibility, ignition mechanisms, and design requirements for oxygen valves
No PTFE in high-pressure oxygen service (> 30 bar GOX) - PTFE can ignite in high-velocity O₂; use PCTFE or metal-to-metal seats instead; PTFE acceptable for low-pressure (<30 bar) LOX
No brass, bronze, or copper alloys - acceptable for low-pressure oxygen, but ASU practice avoids them entirely due to particle contamination risk
Extended bonnet per BS 6364 - minimum 350 mm bonnet extension for valves below −29°C to keep packing above cryogenic zone
Impact testing - all cryogenic valve components must pass Charpy V-notch impact test at −196°C per ASTM A370

Why Takoradi's Offshore Oil & Gas Support (Jubilee & TEN fields) Sector Needs Air Separation Units (ASU) Valves

Takoradi (Sekondi-Takoradi) in Ghana's Western Region is the onshore hub for the country's offshore oil-and-gas industry, serving the Jubilee and TEN FPSO fields, hosting the Ghana Gas Atuabo processing plant, the Takoradi thermal power enclave at Aboadze, and a busy port that handles oil-and-gas logistics and manganese and bauxite exports; upstream support, gas processing, and power generation drive demand for API 6D ball, gate, and check valves in A216 WCB and duplex for oil, gas, and export lines, NACE MR0175 sour-service valves for gas streams, API 609 butterfly valves for cooling and firewater, severe-service control valves and API 526 safety-relief valves for the power plants, and ESD valves for the terminals; ASME B16.34, B16.5, and international offshore/EPC standards apply with full material traceability and PMI; Vajra Industrial Solutions supplies Takoradi oil-and-gas support bases, gas-plant and power operators, and EPC contractors with API 6D, NACE, duplex, and severe-service valve packages with documentation and West Africa delivery. Key facilities in the Takoradi area - including Takoradi port and oil-and-gas free zone, Ghana Gas Atuabo processing plant, Takoradi thermal power enclave (Aboadze) - rely on Cryogenic Ball Valve (LOX Service) for their gas processing (ghana gas atuabo plant) operations. Vajra Industrial Solutions supplies Cryogenic Ball Valve (LOX Service), Cryogenic Gate Valve (LIN/LAR), Globe Valve (Control, Cryogenic), Check Valve (Cryogenic) for air separation units (asu) projects across Western Region, with full ASTM G93 (Oxygen Cleaning) and EIGA Doc 13 (Oxygen Safety) compliance documentation - EN 10204 3.1 material test certificates, API 598 pressure test reports, and third-party inspection co-ordination available for every order.

Delivery to Takoradi

Vajra Industrial Solutions offers export documentation and delivery to Takoradi in 7–14 business days. Emergency dispatch available for plant shutdowns and critical site requirements.

Also serving: Takoradi port and oil-and-gas free zone, Ghana Gas Atuabo processing plant, Takoradi thermal power enclave (Aboadze), Jubilee and TEN FPSO onshore support base

FAQ - Air Separation Units (ASU) Valves in Takoradi

Do you supply air separation units (asu) valves in Takoradi?
Yes. Vajra Industrial Solutions supplies Cryogenic Ball Valve (LOX Service), Cryogenic Gate Valve (LIN/LAR), Globe Valve (Control, Cryogenic), Check Valve (Cryogenic) for air separation units (asu) applications in Takoradi, Western Region. Takoradi (Sekondi-Takoradi) in Ghana's Western Region is the onshore hub for the country's offshore oil-and-gas industry, serving the Jubilee and TEN FPSO fields, hosting the Ghana Gas Atuabo processing plant, the Takoradi thermal power enclave at Aboadze, and a busy port that handles oil-and-gas logistics and manganese and bauxite exports; upstream support, gas processing, and power generation drive demand for API 6D ball, gate, and check valves in A216 WCB and duplex for oil, gas, and export lines, NACE MR0175 sour-service valves for gas streams, API 609 butterfly valves for cooling and firewater, severe-service control valves and API 526 safety-relief valves for the power plants, and ESD valves for the terminals; ASME B16.34, B16.5, and international offshore/EPC standards apply with full material traceability and PMI; Vajra Industrial Solutions supplies Takoradi oil-and-gas support bases, gas-plant and power operators, and EPC contractors with API 6D, NACE, duplex, and severe-service valve packages with documentation and West Africa delivery. We offer export documentation and delivery to Takoradi in 7–14 business days with full documentation and third-party inspection.
What certifications are required for air separation units (asu) valves in Takoradi?
For air separation units (asu) in Takoradi, the applicable standards are: ASTM G93 (Oxygen Cleaning), EIGA Doc 13 (Oxygen Safety), BS 6364 (Cryogenic Valves), ASME B16.34, ISO 21011 (Cryogenic Valves), CGA G-4.1 (O₂ Cleaning USA), API 598. All valves are supplied with full documentation including material test reports (EN 10204 3.1/3.2), pressure test certificates, and dimensional inspection reports. Third-party inspection (TPI) by EIL, Bureau Veritas, Lloyd's Register, or the client's nominated inspector can be arranged.
What is the delivery time for air separation units (asu) valves to Takoradi?
Standard stock sizes: export documentation and delivery to Takoradi in 7–14 business days. Custom sizes and special materials (Duplex, Hastelloy, P91): 4–8 weeks manufacturing lead time. Express dispatch available for urgent site requirements. Contact us at +91-9979774557 or sales@vajravyuh.com with your specification and required delivery date.
What is ASTM G93 oxygen cleaning and is it mandatory for all ASU valves?
ASTM G93 (Standard Practice for Cleaning Methods and Cleanliness Levels for Material and Equipment Used in Oxygen-Enriched Environments) defines the degreasing, rinsing, and verification process for components that will be in contact with oxygen. For LOX and GOX service in ASUs, ASTM G93 cleaning is mandatory - trace hydrocarbons or particles can ignite in an oxygen-rich environment. The process involves solvent degreasing (usually with non-flammable chlorinated solvents or approved alternatives), hot DI water rinse, oven drying, UV light inspection, white-glove testing, and sealing in nitrogen-purged polyethylene bags for shipment.
Why can't I use PTFE seats in high-pressure oxygen valves?
PTFE (polytetrafluoroethylene) is generally oxygen-compatible at low pressures and low flow velocities. However, above approximately 30 bar GOX, PTFE can ignite through frictional heating from high-velocity gas impingement or particle impact ignition - a mechanism unique to oxygen service. EIGA Doc 13 and CGA G-4.1 restrict PTFE in high-pressure oxygen to specific designs with defined velocity limits. PCTFE (polychlorotrifluoroethylene) is the standard alternative - it has a higher ignition temperature than PTFE and is the seat material of choice for high-pressure LOX and GOX valves above 30 bar.

Other Application Guides for Takoradi

Get a Quote

Air Separation Units (ASU) Valves - Takoradi

Send your specification - quote within 24 hours with full documentation.

Standards

ASTM G93 (Oxygen Cleaning)
EIGA Doc 13 (Oxygen Safety)
BS 6364 (Cryogenic Valves)
ASME B16.34
ISO 21011 (Cryogenic Valves)
CGA G-4.1 (O₂ Cleaning USA)
API 598