HomeLocationsRatnagiriAmmonia & Fertiliser Plants

Ratnagiri · Ammonia & Fertiliser Plants

Valves for Ammonia & Fertiliser PlantsRatnagiri

Ratnagiri's Dabhol complex — operated by Ratnagiri Gas & Power Private Limited (RGPPL, a NTPC–GAIL joint venture) — is one of India's largest LNG regasification and combined-cycle power generation facilities, with 5 Mtpa LNG import capacity and 1,967 MW CCGT capacity; the Dabhol LNG terminal requires cryogenic ASTM A182 F316L extended-stem ball valves, cryogenic butterfly valves, and safety relief valves for LNG storage and regasification; Vajra Industrial Solutions supplies IBR-certified steam valves, cryogenic LNG ball valves, and ASME B16.34 Class 300–900 gate valves for RGPPL Dabhol, with 3–5 day delivery from Vadodara.

High-pressure WC9 gate valves, LF2 ball valves, and NACE MR0103-compliant valves for ammonia synthesis loops, urea reactors, and fertiliser production systems.

API 6DAPI 526 (PSV)NACE MR0103ASME B16.34API 598
API 6D Certified
ASME B16.34
ISO 9001:2015
24h Quote

Ammonia & Fertiliser Plants Valves — Available in Ratnagiri

Gate Valve (A217 WC9)

Class 600 / 900 / 1500

High-temperature, high-pressure synthesis loop isolation; hydrogen service at 200–300 bar

Materials: A217 WC9 (Cr-Mo alloy steel), A182 F22 forged for smaller sizes  ·  Standards: API 600, ASME B16.34, API 598
View Gate Valve (A217 WC9) options for Ratnagiri

Ball Valve (A350 LF2)

Class 150 / 300

Cryogenic liquid ammonia storage (−33°C) — extended bonnet, anti-static, fire-safe

Materials: A350 LF2, A182 F316L for urea service; PTFE seats rated to −46°C  ·  Standards: API 6D, API 607, BS 6364 (cryogenic)
View Ball Valve (A350 LF2) options for Ratnagiri

Safety Relief Valve

Class 300 / 600 / 900

Synthesis loop, NH₃ storage sphere, and urea reactor overpressure protection per API 526

Materials: A351 CF8M (SS316), A216 WCB with Stellite trim for high-cycle service  ·  Standards: API 526, API 527, ASME Section VIII
View Safety Relief Valve options for Ratnagiri

Globe Valve (IBR)

Class 300 / 600

Steam service on cogeneration boiler — IBR Form III-C/III-E certification mandatory

Materials: A216 WCB to Class 600; A217 WC6/WC9 for high-temperature steam above 425°C  ·  Standards: IBR 1950, ASME B16.34, IS 9395
View Globe Valve (IBR) options for Ratnagiri

Ammonia & Fertiliser Plants Industry in Ratnagiri

Ratnagiri's Dabhol complex — operated by Ratnagiri Gas & Power Private Limited (RGPPL, a NTPC–GAIL joint venture) — is one of India's largest LNG regasification and combined-cycle power generation facilities, with 5 Mtpa LNG import capacity and 1,967 MW CCGT capacity; the Dabhol LNG terminal requires cryogenic ASTM A182 F316L extended-stem ball valves, cryogenic butterfly valves, and safety relief valves for LNG storage and regasification; Vajra Industrial Solutions supplies IBR-certified steam valves, cryogenic LNG ball valves, and ASME B16.34 Class 300–900 gate valves for RGPPL Dabhol, with 3–5 day delivery from Vadodara.

Power Generation (Dabhol / Ratnagiri Gas & Power)LNG RegasificationChemical & PharmaceuticalPort & LogisticsFisheries & Food

Critical Valve Requirements

Hydrogen service valves must comply with NACE MR0103 (refinery sour service) — hardness limits on body, trim, and fasteners
Ammonia service — extended bonnets for cryogenic applications below −29°C; fire-safe design per API 607
Urea melt valves — SS316L trim with PTFE packing; no copper-based alloys (urea attacks copper)
IBR certification for all steam valves above 3.5 kg/cm² — Form III-C material cert and Form III-E hydraulic test
API 526 compliance for all pressure safety valves; back-pressure correction for superimposed back-pressure
Anti-static and fire-safe design for liquid NH₃ storage valves — API 607 7th edition minimum

Why Ratnagiri's Power Generation (Dabhol / Ratnagiri Gas & Power) Sector Needs Ammonia & Fertiliser Plants Valves

Ratnagiri's Dabhol complex — operated by Ratnagiri Gas & Power Private Limited (RGPPL, a NTPC–GAIL joint venture) — is one of India's largest LNG regasification and combined-cycle power generation facilities, with 5 Mtpa LNG import capacity and 1,967 MW CCGT capacity; the Dabhol LNG terminal requires cryogenic ASTM A182 F316L extended-stem ball valves, cryogenic butterfly valves, and safety relief valves for LNG storage and regasification; Vajra Industrial Solutions supplies IBR-certified steam valves, cryogenic LNG ball valves, and ASME B16.34 Class 300–900 gate valves for RGPPL Dabhol, with 3–5 day delivery from Vadodara. Key facilities in the Ratnagiri area — including RGPPL (Ratnagiri Gas & Power Pvt Ltd) Dabhol LNG Terminal, RGPPL 1,967 MW Combined Cycle Power Plant, Jaigad Port (proposed LNG expansion) — rely on Gate Valve (A217 WC9) for their power generation (dabhol / ratnagiri gas & power) operations. Vajra Industrial Solutions supplies Gate Valve (A217 WC9), Ball Valve (A350 LF2), Safety Relief Valve, Globe Valve (IBR) for ammonia & fertiliser plants projects across Maharashtra, with full API 6D and API 526 (PSV) compliance documentation — EN 10204 3.1 material test certificates, API 598 pressure test reports, and third-party inspection co-ordination available for every order.

Delivery to Ratnagiri

Vajra Industrial Solutions offers delivery to Ratnagiri in 3–7 business days. Emergency dispatch available for plant shutdowns and critical site requirements.

Also serving: RGPPL (Ratnagiri Gas & Power Pvt Ltd) Dabhol LNG Terminal, RGPPL 1,967 MW Combined Cycle Power Plant, Jaigad Port (proposed LNG expansion), GAIL Dabhol LNG import pipeline, Maharashtra chemical cluster (Lote Parshuram MIDC)

FAQ — Ammonia & Fertiliser Plants Valves in Ratnagiri

Do you supply ammonia & fertiliser plants valves in Ratnagiri?
Yes. Vajra Industrial Solutions supplies Gate Valve (A217 WC9), Ball Valve (A350 LF2), Safety Relief Valve, Globe Valve (IBR) for ammonia & fertiliser plants applications in Ratnagiri, Maharashtra. Ratnagiri's Dabhol complex — operated by Ratnagiri Gas & Power Private Limited (RGPPL, a NTPC–GAIL joint venture) — is one of India's largest LNG regasification and combined-cycle power generation facilities, with 5 Mtpa LNG import capacity and 1,967 MW CCGT capacity; the Dabhol LNG terminal requires cryogenic ASTM A182 F316L extended-stem ball valves, cryogenic butterfly valves, and safety relief valves for LNG storage and regasification; Vajra Industrial Solutions supplies IBR-certified steam valves, cryogenic LNG ball valves, and ASME B16.34 Class 300–900 gate valves for RGPPL Dabhol, with 3–5 day delivery from Vadodara. We offer delivery to Ratnagiri in 3–7 business days with full documentation and third-party inspection.
What certifications are required for ammonia & fertiliser plants valves in Ratnagiri?
For ammonia & fertiliser plants in Ratnagiri, the applicable standards are: API 6D, API 526 (PSV), NACE MR0103, ASME B16.34, API 598, IBR (Steam Valves), IS 2825. All valves are supplied with full documentation including material test reports (EN 10204 3.1/3.2), pressure test certificates, and dimensional inspection reports. Third-party inspection (TPI) by EIL, Bureau Veritas, Lloyd's Register, or the client's nominated inspector can be arranged.
What is the delivery time for ammonia & fertiliser plants valves to Ratnagiri?
Standard stock sizes: delivery to Ratnagiri in 3–7 business days. Custom sizes and special materials (Duplex, Hastelloy, P91): 4–8 weeks manufacturing lead time. Express dispatch available for urgent site requirements. Contact us at +91-9979774557 or sales@vajravyuh.com with your specification and required delivery date.
What valve material should I use for anhydrous ammonia service?
For liquid ammonia (−33°C to ambient), use A350 LF2 carbon steel body with PTFE seats and SS316 trim — no copper, brass, or zinc alloys. For synthesis loop gas (H₂/N₂ at 150–300 bar), use A217 WC9 (Cr-Mo alloy) gate valves verified against the API 941 Nelson curves for hydrogen attack. For urea melt (185°C, 150 bar), SS316L is mandatory — carbamate in the loop attacks carbon steel rapidly.
Do ammonia plant valves need NACE MR0103 certification?
NACE MR0103 (Materials Resistant to Sulfphide Stress Cracking in Corrosive Petroleum Refining Environments) applies when H₂S is present — common in ammonia plants using natural gas feedstock via desulphurisation. Key requirement: body and trim hardness ≤ HRC 22 (Rockwell C). If your feedstock is H₂S-free coal or electrolysis, NACE may not be mandatory, but most licensors (Haldor Topsoe, KBR, Casale) specify it as a precaution.

Other Application Guides for Ratnagiri

Get a Quote

Ammonia & Fertiliser Plants Valves — Ratnagiri

Send your specification — quote within 24 hours with full documentation.

Standards

API 6D
API 526 (PSV)
NACE MR0103
ASME B16.34
API 598
IBR (Steam Valves)
IS 2825