HomeLocationsVijayawadaChlor-Alkali Plants

Vijayawada · Chlor-Alkali Plants

Valves for Chlor-Alkali PlantsVijayawada

AP's commercial capital and home to NTPC Vijayawada thermal plant — the new capital Amaravati construction also drives MEP and water valve demand.

PVDF-lined butterfly valves for wet chlorine gas, Hastelloy C-276 and titanium ball valves for hydrochloric acid, and SS316L diaphragm valves for caustic soda (NaOH) service.

ASME B16.34ISO 9001:2015API 609 (Butterfly)EN 12756 (Valve Stuffing Boxes)ATEX / IECEx (Chlorine Zone 1)
API 6D Certified
ASME B16.34
ISO 9001:2015
24h Quote

Chlor-Alkali Plants Valves — Available in Vijayawada

PVDF-Lined Butterfly Valve

PN 10 / PN 16

Wet chlorine gas isolation — PVDF lining (or solid PVDF body) is uniquely resistant to wet Cl₂; titanium disc for highest corrosion resistance

Materials: WCB or SS316 shell; PVDF lining; titanium disc; FKM seat for Cl₂ service  ·  Standards: API 609, Chlorine Institute Pamphlet 6, ATEX Zone 1
View PVDF-Lined Butterfly Valve options for Vijayawada

Hastelloy C-276 Ball Valve

Class 150 / 300

Hydrochloric acid (all concentrations, up to 100°C) — only Hastelloy C-276 and titanium resist HCl above 10% concentration

Materials: Hastelloy C-276 (UNS N10276) body, ball, and stem; PTFE seats  ·  Standards: ASME B16.34, API 607 (fire-safe HCl service)
View Hastelloy C-276 Ball Valve options for Vijayawada

SS316L Diaphragm Valve

PN 10 / PN 16

Caustic soda (NaOH 30–50%) process and transfer — SS316L body with EPDM diaphragm; also used for sodium hypochlorite

Materials: A351 CF3M (SS316L cast) or A182 F316L forged; EPDM diaphragm  ·  Standards: ASME B16.34, DIN 3202 (diaphragm valves)
View SS316L Diaphragm Valve options for Vijayawada

Titanium Ball Valve

Class 150 / 300

Brine service and wet chlorine — Grade 2 titanium resists both Cl₂ and HCl; used in electrolysis cell connections

Materials: Titanium Grade 2 (UNS R50400) body, ball, and stem; PTFE seats  ·  Standards: ASTM B265 (titanium sheet), ASME B16.34
View Titanium Ball Valve options for Vijayawada

Chlor-Alkali Plants Industry in Vijayawada

AP's commercial capital and home to NTPC Vijayawada thermal plant — the new capital Amaravati construction also drives MEP and water valve demand.

Power GenerationPharmaceuticalConstructionFood Processing

Critical Valve Requirements

Wet chlorine gas — PVDF or PTFE-lined body, titanium disc; absolutely no iron, nickel-chromium alloys (attacked by wet Cl₂); no copper; FKM or PTFE packing only
Dry chlorine gas (< 20 ppm moisture) — carbon steel is surprisingly acceptable for dry Cl₂; however most plants keep SS316 or titanium as standard
Hydrochloric acid (all concentrations) — Hastelloy C-276 or titanium; SS316 only for dilute (<5%) cold HCl; NEVER use carbon steel
Caustic soda (NaOH) — SS316L acceptable for <70% NaOH; avoid aluminium (catastrophic SCC in NaOH); EPDM diaphragm valves preferred for slurry-free NaOH
Hydrogen gas from electrolysis — ATEX Zone 1; all electrical components on actuated valves must be Ex-certified
Brine (saturated NaCl) — titanium or rubber-lined butterfly; SS316 not reliable above 60°C in concentrated chloride

Why Vijayawada's Power Generation Sector Needs Chlor-Alkali Plants Valves

AP's commercial capital and home to NTPC Vijayawada thermal plant — the new capital Amaravati construction also drives MEP and water valve demand. Key facilities in the Vijayawada area — including NTPC Vijayawada, AP Genco Thermal Plants, Vijayawada Industrial Area — rely on PVDF-Lined Butterfly Valve for their power generation operations. Vajra Industrial Solutions supplies PVDF-Lined Butterfly Valve, Hastelloy C-276 Ball Valve, SS316L Diaphragm Valve, Titanium Ball Valve for chlor-alkali plants projects across Andhra Pradesh, with full ASME B16.34 and ISO 9001:2015 compliance documentation — EN 10204 3.1 material test certificates, API 598 pressure test reports, and third-party inspection co-ordination available for every order.

Delivery to Vijayawada

Vajra Industrial Solutions offers delivery to Vijayawada in 3–7 business days. Emergency dispatch available for plant shutdowns and critical site requirements.

Also serving: NTPC Vijayawada, AP Genco Thermal Plants, Vijayawada Industrial Area

FAQ — Chlor-Alkali Plants Valves in Vijayawada

Do you supply chlor-alkali plants valves in Vijayawada?
Yes. Vajra Industrial Solutions supplies PVDF-Lined Butterfly Valve, Hastelloy C-276 Ball Valve, SS316L Diaphragm Valve, Titanium Ball Valve for chlor-alkali plants applications in Vijayawada, Andhra Pradesh. AP's commercial capital and home to NTPC Vijayawada thermal plant — the new capital Amaravati construction also drives MEP and water valve demand. We offer delivery to Vijayawada in 3–7 business days with full documentation and third-party inspection.
What certifications are required for chlor-alkali plants valves in Vijayawada?
For chlor-alkali plants in Vijayawada, the applicable standards are: ASME B16.34, ISO 9001:2015, API 609 (Butterfly), EN 12756 (Valve Stuffing Boxes), ATEX / IECEx (Chlorine Zone 1), Chlorine Institute Pamphlet 6. All valves are supplied with full documentation including material test reports (EN 10204 3.1/3.2), pressure test certificates, and dimensional inspection reports. Third-party inspection (TPI) by EIL, Bureau Veritas, Lloyd's Register, or the client's nominated inspector can be arranged.
What is the delivery time for chlor-alkali plants valves to Vijayawada?
Standard stock sizes: delivery to Vijayawada in 3–7 business days. Custom sizes and special materials (Duplex, Hastelloy, P91): 4–8 weeks manufacturing lead time. Express dispatch available for urgent site requirements. Contact us at +91-9979774557 or sales@vajravyuh.com with your specification and required delivery date.
Can I use SS316 valves for chlorine service in a chlor-alkali plant?
No — wet chlorine gas (Cl₂ with moisture) attacks austenitic stainless steel, including SS316. The chromium oxide passive layer that protects SS316 is destroyed by Cl₂ + HCl attack, causing rapid pitting and stress corrosion cracking. For wet chlorine, specify PVDF-lined butterfly valves (PN 10) or titanium ball valves. Dry chlorine (confirmed < 20 ppm moisture) can use carbon steel, but most plants maintain PVDF or titanium as a standard to eliminate moisture moisture monitoring from the maintenance programme.
What valve material handles both chlorine and caustic service?
Titanium Grade 2 is the rare material that resists both wet chlorine gas and dilute caustic soda — making it the preferred choice for brine and cell liquor service where both Cl₂ and NaOH are present. However, titanium is expensive and not suited for concentrated hot NaOH (>70%, above 80°C — risk of titanium stress corrosion cracking in very hot concentrated alkali). For pure caustic service, SS316L diaphragm valves are more economical.

Other Application Guides for Vijayawada

Get a Quote

Chlor-Alkali Plants Valves — Vijayawada

Send your specification — quote within 24 hours with full documentation.

Standards

ASME B16.34
ISO 9001:2015
API 609 (Butterfly)
EN 12756 (Valve Stuffing Boxes)
ATEX / IECEx (Chlorine Zone 1)
Chlorine Institute Pamphlet 6