BS 6364
Standard Specification

BS 6364 Globe Valves

What BS 6364 requires for globe valves — applicability, key and testing requirements, the alternative standards, and compliant supply with full certification.

What does BS 6364 require for globe valves?

BS 6364 (BS 6364 - Specification for Valves for Cryogenic Service, British Standards Institution (BSI)) sets the design, material and testing requirements for globe valves in its scope. BS 6364 is the primary cryogenic valve standard, specifying design and testing requirements for valves used in LNG, liquid nitrogen, liquid oxygen, and other cryogenic services below -46°C.

Applicable Pressure Classes

Class 150Class 300Class 600Class 900

Key Requirements

  • Extended bonnet design mandatory - bonnet length to maintain packing at ambient temperature
  • Body and bonnet materials: A352 LCC (-101°C min), SS316/CF8M (-196°C min)
  • Cold-shock test: valve filled with liquid nitrogen, cycled 10 times, then seat leak tested at cryogenic temperature
  • Low-temperature impact testing per ASTM A370 - minimum 27J Charpy at -196°C for austenitic SS
  • Seat leakage not to exceed Class VI (API 598) when cold-tested
  • Venting provision in body to prevent hydraulic lock from vaporising liquid

Testing Requirements

  • Cold-shock test at -196°C
  • Seat leakage test at cryogenic temperature
  • Low-temperature Charpy impact test

Alternative Standards for Globe Valves

Other standards that also govern globe valves — useful for spec cross-acceptance.

Reviewed by Valve Standards Engineering, Vajra Industrial SolutionsDiscipline: Industrial Valve Standards & ComplianceLast reviewed: 20 June 2026

Connected Engineering

Need BS 6364 globe valves?

We supply BS 6364-compliant globe valves with full certification — share your size, class and service for a 24-hour quote.