Desalination & High-Purity Water
Application Specification

Butterfly Valves for Desalination & High-Purity Water

Duplex stainless and SS 316 butterfly valves, ball valves, check valves, and diaphragm valves for SWRO, BWRO, MSF, and MED desalination plants and industrial high-purity water systems.

Which butterfly valves are used for desalination & high-purity water?

Seawater reverse osmosis (SWRO), brackish water RO (BWRO), multi-stage flash (MSF), and multi-effect distillation (MED) desalination plants operate at the intersection of aggressive seawater chemistry and demanding process requirements. Seawater at high chloride concentrations (up to 45,000 ppm TDS) requires duplex stainless or super duplex materials for wetted components; high-pressure RO membranes (55–80 bar for SWRO) demand Class 600+ valves; and permeate water quality requires non-leaching, potable water-compatible materials.

Butterfly Valve (Duplex / Super Duplex)

Seawater intake, brine reject, and concentrate disposal lines - high-chloride environment requires duplex minimum

MaterialsDuplex UNS S31803 body and disc, or Super Duplex UNS S32750 for high-temperature or severe service, EPDM seat
Pressure ClassPN 10 / PN 16 / Class 150
StandardsAWWA C504, EN 593, ISO 9001

Critical Requirements

  • Duplex (UNS S31803) or Super Duplex (UNS S32750) for all seawater-wetted valve components - PREN ≥35 minimum
  • NSF 61 / NSF 372 compliance for all materials in contact with potable water (permeate side)
  • High-pressure rating (Class 300–600) for SWRO membrane inlet and inter-stage boost pumping
  • Oxygen-compatible materials for media containing dissolved oxygen (DO) - relevant for permeate remineralisation and aeration
  • AWWA C504/C516 compliance for large-diameter butterfly valves (DN 200–DN 2400) on intake and discharge
  • Actuation for automated operation - SWRO plants require pneumatic or electric actuators for rapid membrane protection on pump trip

Service Challenges

  • Seawater (35,000–45,000 ppm TDS, high Cl⁻) - chloride pitting corrosion; duplex or super duplex mandatory for structural components
  • Brine reject (80,000+ ppm TDS at 50% recovery) - concentrated seawater with accelerated corrosivity
  • Antiscalant-dosed RO feed - verify elastomer compatibility with antiscalant chemicals at service concentration
  • Chlorinated seawater (pre-treatment disinfection, 0.5–2 ppm Cl₂) - EPDM seats, FBE coated iron for non-wetted components
  • Permeate water (highly purified, low mineral content, corrosive to carbon steel) - SS 316L or PVDF-lined for permeate-side piping

Vajra Butterfly Valves

Compact and efficient butterfly valves for large-scale flow control and isolation.

See the full Butterfly Valves range

Other valves for desalination & high-purity water

Butterfly Valves for other applications