Nuclear Power Plants
Application Specification

Gate Valves for Nuclear Power Plants

ASME Section III Class 2/3 gate, globe, and check valves with N-stamp traceability for nuclear power plant balance-of-plant, auxiliary, and spent-fuel cooling systems.

Which gate valves are used for nuclear power plants?

Nuclear power plants demand the most stringent valve qualification programme in any industry - ASME Section III Class 1/2/3 design and fabrication rules, N-stamp third-party oversight, seismic qualification to IEEE 344, and MOV actuator qualification to IEEE 382. Vajra Industrial Solutions supplies ASME Section III Class 2 and Class 3 valves for balance-of-plant (BOP) systems - auxiliary cooling, spent fuel pool cooling, condensate, feedwater, and service water - with complete QA/QC documentation traceable to 10 CFR 50 Appendix B in international projects and AERB guidelines in India.

Gate Valve (ASME Sec. III Cl.2)

Main isolation on auxiliary cooling, emergency core cooling (ECCS) suction, and spent fuel pool cooling

MaterialsA351 CF8M (SS316 cast), A182 F316 forged (Class 2); WCB with SS316 trim (Class 3)
Pressure ClassClass 150 / 300 / 600 (ASME B16.34 ratings)
StandardsASME Section III NB/NC/ND, ASME B16.34, ASME B16.10

Critical Requirements

  • ASME Section III Class 2/3 design: complete material traceability (Certified Material Test Reports - CMTRs) for all pressure-boundary components
  • N-stamp or NA-stamp: third-party ASME Nuclear Inspector oversight for Class 2 and above
  • Seismic qualification per IEEE 344 - valves on safety-related systems must withstand Operating Basis Earthquake (OBE) and Safe Shutdown Earthquake (SSE)
  • Motor-operated valves (MOVs) qualified per IEEE 382 - torque, voltage variation, and harsh-environment performance testing
  • QA programme per 10 CFR 50 Appendix B (USA) or AERB Safety Guide (India) - design control, procurement document control, inspection, and test records
  • No substitution of materials without NCR (Non-Conformance Report) and AERB/NRC approval - traceability is mandatory

Service Challenges

  • Primary coolant (reactor-grade water) - ultra-low chloride (<0.1 ppm); SS316L or Alloy 600 trim to avoid stress corrosion cracking
  • Borated water - boric acid corrosion; SS316 or high-alloy materials mandatory
  • Heavy water (D₂O) - CANDU/PHWR reactors; no moisture absorption; all valve internals must be compatible with D₂O chemistry
  • Steam and feedwater - IBR certification mandatory in India; ASME B31.1 code compliance
  • Service water (raw river/sea water) - rubber-lined butterfly valves or duplex stainless for seawater

Vajra Gate Valves

Robust gate valves for full-flow isolation and on-off service in various industrial systems.

See the full Gate Valves range

Other valves for nuclear power plants

Gate Valves for other applications

Reviewed by Product Engineering, Vajra Industrial SolutionsDiscipline: Valve Product EngineeringLast reviewed: 20 June 2026

Connected Engineering

Need gate valves for nuclear power plants?

Send your line list or datasheet — we supply gate valves for nuclear power plants to the right material, class and standard with full certification and a 24-hour quote.