Seawater service
Service Selection

Gate Valves for Seawater Service

Which gate valves configuration suits Seawater, in which material, to which standard — from real service data, with the pitfalls flagged.

Which gate valves for Seawater?

Duplex 2205 gate valve - Seawater isolation in subsea and offshore process systems Typical service window: 0.5–25 bar - seawater lift to process system, 0–40°C (ambient seawater); up to 120°C in desalination brine.

Recommended Configurations

Duplex 2205 gate valve

Seawater isolation in subsea and offshore process systems

Body Material for Seawater

Rated from real compatibility data - click any material for the full decision page.

Governing Standards for Seawater Service

NORSOK M-001 (offshore materials selection)DNV-RP-B401 (cathodic protection)ASTM A890 Grade 5A (super-duplex)ASME B16.34

What to Avoid in Seawater Service

  • Carbon steel without cathodic protection and coating
  • Standard 304 or 316 stainless steel valves
  • Valves with aluminium bronze trim in high-velocity seawater

Service Considerations

  • PREN (Pitting Resistance Equivalent Number) ≥ 40 required for offshore seawater
  • Anti-fouling coatings or PTFE lining to prevent biofouling
  • Cathodic protection (zinc anodes) for submerged valves
  • All crevices must be minimised - NORSOK M-001 crevice-free design
  • Full-bore valves preferred to minimise biofouling accumulation

Other valve types for Seawater

Gate Valves for other services

Reviewed by Process Engineering, Vajra Industrial SolutionsDiscipline: Process & Fluid Service EngineeringLast reviewed: 20 June 2026

Connected Engineering

Need gate valves for Seawater service?

Send your conditions - we confirm the configuration and material for Seawater and quote with full certification in 24 hours.